We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Chlorine meter.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Chlorine meter×サニー・トレーディング - List of Manufacturers, Suppliers, Companies and Products

Chlorine meter Product List

1~8 item / All 8 items

Displayed results

High-precision measurement even in harsh environments: Q46H/79S Total Chlorine Meter [ATI]

Due to the unique measurement method, the sample and sensor are non-contact. Even in harsh environments, monitoring measurements of "total chlorine" can be performed with high accuracy.

The Q46H/79S total chlorine meter is resistant to interference from contaminants and can measure total chlorine concentration with high precision. It features a unique structure that prevents contact between the measurement liquid and the sensor, and it has a proven track record in special applications worldwide, such as drinking water, wastewater, and cooling towers. 【Features】 - High precision - Capable of handling a wide range of applications - Measures by gasifying the sample liquid

  • 1358.gif
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study Collection] ATI Residual Chlorine Meter

This is a collection of case studies on ATI residual chlorine meters.

We have compiled case studies that leverage the features of diaphragm-type polarographic sensors.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Residual Chlorine Meter / Total Chlorine Meter DPDSense

These are free residual chlorine meters and total residual chlorine meters using the online DPD method manufactured by Process Instruments.

DPDSense uses 520nm emitted light to detect color changes when DPD reacts with chlorine to form a pink solution. The intensity of the pink color (light absorption) is proportional to the amount of free chlorine and total chlorine present in the sample. This technology is widely accepted around the world as a standard method for online monitoring of residual chlorine levels in water. DPDSense can measure free chlorine, total chlorine, or both. *For more details, please download the PDF or feel free to contact us.*

  • ret.png
  • Other measurement, recording and measuring instruments
  • Disinfectant
  • Food Testing/Analysis/Measuring Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ATI Q46H/62-63 Type Residual Chlorine Meter [Diaphragm Type Sensor]

This is a diaphragm-type polarographic sensor that can be used for a wide range of residual chlorine measurement applications, including pure water, seawater, wastewater, food, and groundwater.

The Q46H/62-63 residual chlorine meter adopts a polarographic membrane sensor, allowing for the direct measurement of free chlorine, active chlorine, and combined chlorine (monochloramine) without the need for reagents. Due to its diaphragm-type sensor, it is less affected by changes in the measurement liquid or impurities, enabling the measurement of residual chlorine in electrolyzed hypochlorous water, seawater, wastewater, hot springs, and pure water. Additionally, since the electrode does not come into direct contact with the measurement liquid, it is less prone to contamination and has a long lifespan. By adding a pH sensor option, simultaneous measurement of chlorine and pH is possible. The pH correction function allows for measurements even when the pH value is high or fluctuating. It has a wide measurement range, capable of measuring low concentrations below 1 mg/L and high concentrations above 100 mg/L with a single unit. 【Features】 ■ No reagents required ■ Easy installation ■ Wide and flexible measurement range ■ Cost-effective *Demo units are available, so please feel free to inquire. *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ATI "Q46H/79PR Model" Total Chlorine Meter

After chloramine treatment, it is suitable for managing effective chlorine after sterilization and disinfection.

The "Q46H/79PR type" is a total chlorine meter that allows for inline continuous measurement without reagents. It is suitable for managing effective chlorine (free chlorine and combined chlorine) after chloramine treatment and disinfection. Additionally, it can be used in seawater or low conductivity environments without the need for chemical reagent additions. Furthermore, options for pH measurement and additional outputs are available. 【Features】 ■ Inline continuous measurement without reagents ■ No need for chemical reagent additions ■ Usable in seawater and low conductivity environments ■ Options for pH measurement and additional outputs available *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Dio Sense Chlorine Dioxide Meter

It is a diaphragm-type sensor that is not affected by chlorine, does not use reagents, is very stable, and minimizes maintenance effort and lifecycle.

The DioSense sensors and flow cells come with different controllers, offering various options for communication, display, and control, even with the same performance. They can also be installed on various flow cells and automatic cleaning devices.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Online Membrane-Type Residual Chlorine Meter T4055

We can provide an affordable online measurable residual chlorine meter.

- Due to its diaphragm type, it has a structure that is less susceptible to interference from other components. - pH measurement is available as an option. - It meets the IP65 standard for waterproof and dustproof specifications. (Sensor: IP68) - It has an easily maintainable design structure.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Instran Online Chlorine Meter

Continuous measurement of total chlorine concentration in water using an ion-selective electrode method!

Advantages This method is a very simple chlorine measurement technique. It consumes a small amount of reagents, and chromate ions, which interfere in amperometric methods, do not cause interference here. Conductivity and calcium, which are significant interferences in the DPD method, do not interfere either. Measurement Principle – ISE Electrode Analysis is performed using the Standard Known Addition (SKA) method. Two measurements are taken, and the concentration is calculated from the difference between the two and the slope during the calibration curve creation. The reference for calculating the results is not an absolute value but the relative difference in mV, so any changes that may occur in the matrix sample are corrected by both of these lectures. This allows for the avoidance of external interference. Measurement Method It is based on the measurement of iodide. Through the reaction of chlorine, buffer solution, and potassium iodide reagent, chlorine reacts with potassium, releasing iodide. Chlorine displaces iodide. Subsequently, the ISE electrode measures the iodide, and the amount of iodide measured corresponds to the chlorine in the sample.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration